Tooth Shade Selection by Tooth Color Shade Guide and Tooth Color Matching Instrument in Dentistry
The precisely tooth shade selection that harmoniously with adjacent teeth impacted on patient satisfaction of the treatment. Nowadays, the tooth shade selection can be divided into visual method and color measuring devices. However, the visual method was required the practitioner’s experience subjective and was influenced by various factors caused an error of tooth shade selection, whereas the color measuring devices was aimed to reduce or overcome imperfections and inconsistencies of traditional shade matching. the color measuring devices has been continuously developed until now. the devices are more accuracy than visual method.
1. Igiel C, Weyhrauch M, Wentaschek S, et al. Dental color matching: A comparison between visual and instrumental methods. Dent Mater J 2016; 35(1): 63-69.
2. Lehmann KM, Devigus A, Igiel C, et al. Repeatability of color-measuring devices. Eur J Esthet Dent 2011; 6(4): 428-435.
3. Chu SJ, Trushkowsky RD, Paravina RD. Dental color matching instruments and systems. Review of clinical and research aspects. J Dent 2010; 38: 2-16.
4. Pimental W, Tiossi R. Comparison between visual and instrumental methods for natural tooth shade matching. Gen Dent 2014; 62(6): 47-49.
5. Igiel C, Lehmann KM, Ghinea R, et al. Reliability of visual and instrumental color matching. J Esthet Restor Dent 2017; 29(5): 303-308.
6. Della Bona A, Barrett AA, Rosa V, et al. Visual and instrumental agreement in dental shade selection: three distinct observer populations and shade matching protocols. Dent Mater 2009; 25(2): 276-281.
7.Terry DA, Geller W, Tric O, et al. Anatomical form defines color: function, form, and aesthetics. Pract Proced Aesthet Dent 2002; 14(1): 59-67.
8. Munsell.com [https://munsell.com/about-munsell-color/how-color-notation-works] [updated 2018; cited 2018 May 4]. Available from: http:// www.munsell.com.
9. Sikri VK. Color: Implications in dentistry. J Conserv Dent 2010; 13(4): 249-255.
10. Brewer JD, Wee A, Seghi R. Advances in color matching. Dent Clin North Am 2004; 48(2): 341-358.
11. Russell MD, Gulfraz M, Moss BW. In vivo measurement of colour changes in natural teeth. J Oral Rehabil 2000; 27(9): 786-792.
12. Fondriest J. Shade matching in restorative dentistry: the science and strategies. Int J Periodontics Restorative Dent 2003; 23(5): 467-479.
13. Pensler AV. Shade selection: problems and solutions. Compend Contin Educ Dent 1998; 19(4): 387-390.
14. Schwabacher WB, Goodkind RJ. Three-dimensional color coordinates of natural teeth compared with three shade guides. J Prosthet Dent 1990; 64(4): 425-431.
15. Chu SJ, Tarnow DP. Digital shade analysis and verification: a case report and discussion. Pract Proced Aesthet Dent 2001; 13(2): 129-136.
16. Hasegawa A, Ikeda I, Kawaguchi S. Color and translucency of in vivo natural central incisors. J Prosthet Dent 2000; 83(4): 418-423.
17. Burkinshaw SM. Colour in relation to dentistry. Fundamentals of colour science. Br Dent J 2004; 196(1): 33-41.
18. O'Brien WJ, Hemmendinger H, Boenke KM, et al. Color distribution of three regions of extracted human teeth. Dent Mater 1997; 13(3): 179-185.
19. Dozic A, Kleverlaan CJ, Aartman IH, et al. Relations in color among maxillary incisors and canines. Dent Mater 2005; 21(3): 187-191.
20. Hugo B, Witzel T, Klaiber B. Comparison of in vivo visual and computer-aided tooth shade determination. Clin Oral Investig 2005; 9(4): 244-250.
21.Li Q, Wang YN. Comparison of shade matching by visual observation and an intraoral dental colorimeter. J Oral Rehabil 2007; 34(11): 848-854.
22. van der Burgt TP, ten Bosch JJ, Borsboom PC, et al. A comparison of new and conventional methods for quantification of tooth color. J Prosthet Dent 1990; 63(2): 155-162.
23. Lim HN, Yu B, Lee YK. Spectroradiometric and spectrophotometric translucency of ceramic materials. J Prosthet Dent 2010; 104(4): 239-246.
24. Paul SJ, Peter A, Rodoni L, et al. Conventional visual vs spectrophotometric shade taking for porcelain-fused-to-metal crowns: a clinical comparison. Int J Periodontics Restorative Dent 2004; 24(3): 222-231.
25. Khurana R, Tredwin CJ, Weisbloom M, et al. A clinical evaluation of the individual repeatability of three commercially available colour measuring devices. Br Dent J 2007; 203(12): 675-680.
26.Kielbassa AM, Beheim-Schwarzbach NJ, Neumann K, et al. In vitro comparison of visual and computer-aided pre- and post-tooth shade determination using various home bleaching procedures. J Prosthet Dent 2009; 101(2): 92-100.
27. Lagouvardos PE, Fougia AG, Diamantopoulou SA, et al. Repeatability and interdevice reliability of two portable color selection devices in matching and measuring tooth color. J Prosthet Dent 2009; 101(1): 40-45.
28. Da Silva JD, Park SE, Weber HP, et al. Clinical performance of a newly developed spectrophotometric system on tooth color reproduction. J Prosthet Dent 2008; 99(5): 361-368.
29. Vita-zahnfabrik.com [http://www.vita-zahnfabrik.com/resourcesvita/shop/en/en_3055212.pdf] [updated 2018; cited 2018 May 4]. Available from: http:// www.vita-zahnfabrik.com.
30. Ristic I, Paravina R. Color measuring instruments. Acta Stomatologica Naissi 2009; 25:925–932.
31. Mht.ch [http://www.mht.ch/index.php?uri=micro.html] [updated 2018; cited 2018 May 4]. Available from: http:// www.mht.ch.
32. Kim-Pusateri S, Brewer JD, Davis EL, et al. Reliability and accuracy of four dental shade-matching devices. J Prosthet Dent 2009; 101(3): 193-199.
33. Xrite.com [http://www.xrite.com/product_overview.aspx?ID=339] [updated 2018; cited 2018 May 4]. Available from: http:// www.xrite.com
34. ShadeEye-NCC [https://www.nature.com/articles/4813167]: Nature Publishing Group; 2006 [updated 01/14/online; cited 2018 May 4]. 53]. Available from: https:// www.nature.com.
35. Blaes J. Today’s technology improves the shade-matching problems of yesterday. J Indiana Dent Assoc 2002-2003; 81: 17-19.
36. Wee AG, Lindsey DT, Kuo S, et al. Color accuracy of commercial digital cameras for use in dentistry. Dental materials : official publication of the Academy of Dental Materials 2006; 22(6): 553-559.
37. Imai FH. Reviewing state-of-art imaging modalities and its potential for biomedical applications. J Dent 2009; 37: 7-14.
38. Olympus-global.com [http://www.olympus-global.com/en/news/2006b/nr061113crystale.html] [updated 2018; cited 2018 May 4]. Available from: https:// www.olympus-global.com.